Power Configuration:
A200: 200 kW | A300: 300 kW | A400: 400 kW
Upgradable from 200 kW to 400 kW or from 300 kW to 400 kW
DC Output:
Output current: CCS/NACS (liquid-cooled): 600 A continuous | CCS (phase-cooled): 600 A peak | NACS (non-cooled): 375 A continuous
Dynamic Power Sharing: 50 kW granularity¹
Output voltage: 150 - 980 V
Number of outlets: dual outlet
Power conversion efficiency: up to 97%
Standby power: 156 W
AC Input:
Nominal voltage: (CE): 400 Vac (±10%) (NA): 480 Vac (-7%/+10%)
Nominal input current (RMS): A200: (CE): 306 A (NA): 255 A | A300: (CE): 460 A (NA): 383 A | A400: (CE): 612 A (NA): 496 A
Frequency: (CE): 47 - 63 Hz (NA): 60 Hz (±5%)
Earthing systems: (CE): TN-C, TN-C-S, TN-S, TT (NA): WYE
Inlet cable size per phase (no neutral): up to 2 x 300 mm² (600 kcmil) or 4 x 240 mm² (500 kcmil)
Maximum temperature rating for AC inlet cables: 90°C (194°F)
Power factor: > 0.99 at full load
Total Harmonic Distortion (THD): < 3%
Overvoltage category: III
SPD: (CE): Type 1 + 2 (NA): Type 1
SCCR: (CE): 50 kA (NA): 65 kA
Display:
Type: 32” HD full-color anti-glare LCD; Brightness: 1300 nits
Contrast: 1000:1; Interface: 4 push buttons
HMI Configuration:
Info modules: pricing, payment method, help content, idle state info
Branding modules: brand color and logo, app QR code, outro screen
Languages:
English, French, Spanish, German, Italian, Norwegian, Dutch, Swedish, Danish, Turkish, Portuguese, Slovenian, Bulgarian, Polish, Lithuanian, Czech
Connector Options:
CCS1/2 liquid-cooled, or phase-cooled
NACS liquid-cooled, or non-cooled
Cable Management System (CMS):
2 x integrated self-retracting swing arm
Cable Options:
Length: 4.8 m (15.7 ft); Reach: 3.5 m (11.4 ft)
Length: 7 m (22.9 ft); Reach: 5.5 m (15.8 ft) with CMS, 6.3 m (20.7 ft) no CMS
Type: Non-cooled, Liquid-cooled (4.8 m/15.7 ft only)
Lighting:
Roof: 360° dual RGBW LED strips; Gun holder: RGBW LEDs
Authentication Methods:
RFID, Autocharge, Plug & Charge, credit/debit card, mobile app
RFID System:
Mifare ISO 14443 A/B to part 4 and ISO15693, ISO18092/ECMA-340 (NFC). Others available on request.
Remote Management:
Access control, configuration, diagnostics, software updates²
Operating Conditions:
Operating from -30°C to 55°C (-22°F to 131°F) with derating
Storage from 5°C to 40°C (41°F to 104°F), IEC 60721-3-1
Altitude: 2000 m (6562 ft)
Humidity: up to 95%, non-condensing
Impact resistance: IK10
IP rating: IP54, NEMA 3R, indoor and outdoor rated
Noise emission average within 1 m radius, at 25°C (77°F), full power:
A200: 62 dB(A) | A300: 64 dB(A) | A400: 65 dB(A)
Intended use: indoor and outdoor
Mounting options: floor mounted
Environment pollution degree: Class 3 (outside), Class 2 (inside)
Form Factor:
Dimensions of charger body (H x W x D):
2256 x 790 x 810 mm (88.8 x 31.1 x 31.9 in) (antenna excluded)
Weight: A200: 560 kg (1235 lbs) | A300: 645 kg (1422 lbs)
A400: 730 kg (1610 lbs)
Accessibility: meets ADA requirements for height, reach,
and user interface.
Enclosure type: Stainless Steel and Aluminum
Corrosion resistance: C5-H, ISO 12944
Safety Standards:
(CE): IEC 61851-1, IEC 61851-23
(NA): UL 2202, UL 2231-1, UL 2231-2, CSA 22.2 No.346:22
Metering:
(CE): Eichrecht, MID, LNE (NA): CTEP/NTEP
EMC:
(CE): IEC 61851-21-2 (NA): FCC 47 CFR Part 15B (Class A)
Manufactured:
USA & Europe
Network Connections:
3G/4G/5G, Ethernet (10/100 Base-T), optional second modem
OCPP:
Open Charge Point Protocol (OCPP) 1.6J and 2.0.1
Vehicle Communication Protocol:
DIN SPEC 70121, ISO 15118-2, ISO 15118-3, Autocharge,
Plug & Charge
RED Directive:
ETSI EN 300 330, ETSI EN 301 489-1, ETSI EN 301 489-3,
ETSI 301 489-52, ETSI EN 301 908-13, EN 50364 (RFID),
IEC 62311: 2019, EN IEC 62311: 2020 (4G test)
Sustainability:
ISO 14025 Environmental Product Declaration,
A200 | A300: ENERGY STAR
Additional Standards:
DC Vehicle connector compliant with IEC 62196-1, IEC 62196-3,
Cabinet IP rating according to IEC 60529
Expected Lifespan:
10 years³
³ Expectation based on uninterrupted Service Package coverage, possible refurbishment based on use, and use in suitable environmental conditions, including limited proximity to sea water, conductive dust, and condensing humidity.